Public report sample. Retained results from one dairy delivery, with local paths and source files omitted. Read the explanation.

Brief and requirement coverage

Brief provided: Yes. Mapping review: pending.

Passing mapped checks does not prove that the whole brief was interpreted correctly. Coverage below is recorded scope, not inferred completeness.

Map authored by the producing agent from the owner-supplied brief; tolerances are agent decisions.

Source files supplied with the brief

FileRoleDescriptionSource location
briefs/01-requirements-brief.mdTextOwner-supplied requirements brief v0.1
PDF page or region
null

Mapped requirements

RequirementSourceMapped checksResult / coverageAI routing
Metres, Z-up, explicit stage units (brief s.7)units-axeshuman01-requirements-brief.md (owner-supplied)spec.unitsPASS

Mapped checks ran; mapping review pending

Coverage limits
{
  "extent": "full",
  "reason": "Directly measured"
}
Routine handling
Equipment, pipes, structure, annotations, lights, cameras in separate named groups (s.7)named-groupshuman01-requirements-brief.md (owner-supplied)spec.groupsPASS

Mapped checks ran; mapping review pending

Coverage limits
{
  "extent": "partial",
  "reason": "Counts groups, not their content"
}
Insufficient context
>= 2.2 m head clearance where pipes cross walking routes (s.4)head-clearancehuman01-requirements-brief.md (owner-supplied)spec.headroom.l-101.s1.a2_service, spec.headroom.l-103.s3.a3_west, spec.headroom.l-207.s4.a4_east, spec.headroom.l-308.s2.a4_east, spec.headroom.l-411.s0.a2_service, spec.headroom.l-412.s0.a2_service, spec.headroom.l-413.s0.a2_service, spec.headroom.l-413.s0.a5_process, spec.headroom.l-414.s0.a2_service, spec.headroom.l-415.s0.a2_service, spec.headroom.l-416.s0.a2_service, spec.headroom.l-422.s1.a2_service, spec.headroom.l-423.s1.a2_service, spec.headroom.l-423.s1.a5_process, spec.headroom.l-424.s1.a2_service, spec.headroom.l-425.s1.a2_service, spec.headroom.l-501.s0.a2_service, spec.headroom.l-501.s0.a5_process, spec.headroom.l-502.s2.a2_service, spec.headroom.l-502.s2.a5_process, spec.headroom.l-511.s0.a2_service, spec.headroom.l-511.s0.a5_process, spec.headroom.l-512.s2.a2_service, spec.headroom.l-512.s2.a5_process, spec.headroom.l-503.s0.a2_service, spec.headroom.l-504.s3.a2_service, spec.headroom.l-513.s0.a2_service, spec.headroom.l-514.s2.a2_service, spec.headroom.l-521.s0.a2_service, spec.headroom.l-521.s0.a5_process, spec.headroom.l-522.s0.a2_servicePASS

Mapped checks ran; mapping review pending

Coverage limits
{
  "extent": "partial",
  "reason": "Only crossings found by the builder analysis are bound; bounding-box gap of whole segment meshes"
}
Insufficient context
Building approx. 24 m x 16 m, 6 m clear height (s.1)envelopehuman01-requirements-brief.md (owner-supplied)spec.env.x, spec.env.y, spec.env.zPASS

Mapped checks ran; mapping review pending

Coverage limits
{
  "extent": "partial",
  "reason": "Agent decision: \"approximately\" read as a minimum interior gap; no upper bound is checked"
}
Human review needed
Equipment and overhead connections fit under the roof (s.4)fits-buildinghuman01-requirements-brief.md (owner-supplied)spec.fits.0, spec.fits.1, spec.fits.2, spec.fits.3, spec.fits.4, spec.fits.5, spec.fits.6PASS

Mapped checks ran; mapping review pending

Coverage limits
{
  "extent": "partial",
  "reason": "Selected tallest items only"
}
Insufficient context
Reserved areas: milk skid ~5x3 m, cream skid ~3x2 m, CIP ~4x3 m (s.3)skid-reserveshuman01-requirements-brief.md (owner-supplied)spec.reserve.hx101, spec.reserve.hx201, spec.reserve.cip401PASS

Mapped checks ran; mapping review pending

Coverage limits
{
  "extent": "partial",
  "reason": "Frame footprint only; separator 2x2 m zone has no single mesh"
}
Human review needed
Principal pipes meet equipment nozzles (s.3) / connect to visible ports (s.8)pipe-port-connectionshuman01-requirements-brief.md (owner-supplied)spec.conn.l-101.start, spec.conn.l-101.end, spec.conn.l-102.end, spec.conn.l-103.start, spec.conn.l-103.end, spec.conn.l-104.start, spec.conn.l-105.start, spec.conn.l-105.end, spec.conn.l-106.start, spec.conn.l-106.end, spec.conn.l-107.start, spec.conn.l-107.end, spec.conn.l-201.start, spec.conn.l-201.end, spec.conn.l-202.start, spec.conn.l-202.end, spec.conn.l-203.start, spec.conn.l-203.end, spec.conn.l-204.start, spec.conn.l-204.end, spec.conn.l-205.start, spec.conn.l-205.end, spec.conn.l-206.start, spec.conn.l-206.end, spec.conn.l-207.start, spec.conn.l-207.end, spec.conn.l-208.start, spec.conn.l-301.start, spec.conn.l-301.end, spec.conn.l-302.start, spec.conn.l-302.end, spec.conn.l-303.start, spec.conn.l-303.end, spec.conn.l-304.start, spec.conn.l-304.end, spec.conn.l-305.start, spec.conn.l-305.end, spec.conn.l-306.start, spec.conn.l-306.end, spec.conn.l-307.start, spec.conn.l-307.end, spec.conn.l-308.start, spec.conn.l-308.end, spec.conn.l-309.start, spec.conn.l-401.start, spec.conn.l-411.end, spec.conn.l-412.end, spec.conn.l-413.end, spec.conn.l-414.end, spec.conn.l-415.end, spec.conn.l-416.end, spec.conn.l-420.end, spec.conn.l-501.end, spec.conn.l-502.start, spec.conn.l-511.end, spec.conn.l-512.start, spec.conn.l-503.end, spec.conn.l-504.start, spec.conn.l-513.end, spec.conn.l-514.start, spec.conn.l-521.end, spec.conn.l-522.end, spec.conn.l-523.endPASS

Mapped checks ran; mapping review pending

Coverage limits
{
  "extent": "partial",
  "reason": "Transform-level: detects equipment moved after piping; does not inspect mesh vertices"
}
Human review needed
Brushed stainless equipment/pipework, painted motors/cabinets, epoxy floor (s.5)materialshuman01-requirements-brief.md (owner-supplied)spec.materialsUNKNOWN

Partial automation; separate review required

Coverage limits
{
  "extent": "partial",
  "reason": "Representative bindings to the scene's named materials; appearance needs visual review"
}
Human review needed
Readable equipment tags (s.5)label-textureshuman01-requirements-brief.md (owner-supplied)spec.tex.sep-101, spec.tex.hx-101, spec.tex.tk-301, spec.tex.cip-401UNKNOWN

Partial automation; separate review required

Coverage limits
{
  "extent": "partial",
  "reason": "Selected tag textures decode; legibility needs visual review"
}
Human review needed
Trace raw milk to separator and both streams to their own treatment and storage (s.8)trace-routeshuman01-requirements-brief.md (owner-supplied)No scripted checkUNKNOWN

No automated coverage

Coverage limits
{
  "extent": "unreviewed",
  "reason": "Not measurable by the registered check types"
}
Human review needed
Forward and diversion routes visible; no raw-milk bypass into storage (s.8)forward-diversionhuman01-requirements-brief.md (owner-supplied)No scripted checkUNKNOWN

No automated coverage

Coverage limits
{
  "extent": "unreviewed",
  "reason": "Not measurable by the registered check types"
}
Human review needed
Plate pack, holding section and separator recognizable in close-up (s.8)recognizablehuman01-requirements-brief.md (owner-supplied)No scripted checkUNKNOWN

No automated coverage

Coverage limits
{
  "extent": "unreviewed",
  "reason": "Not measurable by the registered check types"
}
Human review needed
Usable lighting and legible labels (s.8)lighting-labelshuman01-requirements-brief.md (owner-supplied)No scripted checkUNKNOWN

No automated coverage

Coverage limits
{
  "extent": "unreviewed",
  "reason": "Not measurable by the registered check types"
}
Human review needed
No obvious intersections or floating assets (s.8)no-clasheshuman01-requirements-brief.md (owner-supplied)No scripted checkUNKNOWN

No automated coverage

Coverage limits
{
  "extent": "unreviewed",
  "reason": "Not measurable by the registered check types"
}
Human review needed

Open scope gaps

Recorded gaps
[
  "The caller has not completed review of the requirement-to-evidence mapping"
]